HLK-PM01 HLK-PM03 HLK-PM12 AC-DC 220V to 5V/3.3V/12V mini power supply module,intelligent household switch power supply module
$22.03
$28.42
Description HLK-PM01 Product Features: 1). The ultra-thin, subminiature 2). The full voltage input (90 ~ 264 Vac) 3). Low ripple and low noise 4). Output overload short circuit protection function 5). High efficiency and power density 6). Product design to meet the EMC and safety testing requirements 7). Low power consumption, green environmental protection, no-load loss < 0.1 W 8). 100% load test 9). Meet the requirements of UL, CE, 2. Environmental Conditions 1). Working temperature: -20- 60 Celsius 2). Storage temperature: -40- 80 Celsius 3). Relative Humidity: 5-95% 4). Cooling: natural cooling 5). Atmospheric pressure: 80-106 Kpa 6). Altitude: ≤2000m 7). Vibration: Vibration coefficient 10 ~ 500Hz, 2G10min / 1cycle, 60min.each along X, Y, Z axes 3.Electrical Characteristics (at ambient temperature test) 1). Rated input voltage: 100-240 VAc 2). Input voltage range: 90-264VAc 3). Maximum input current: ≤0.2A 4). Input current surge: ≤10A 5). Maximum input voltage: ≤270VAc 6). Enter slow start: ≤50mS 7). Input Low Voltage Efficiency: Vin = 110VAc, full load ≥69% 8). Input High Voltage Efficiency: Vin = 220VAc, full load ≥70% 9). Long-term reliability: MTBF≥100,000h 10). Load rated output voltage: 5 ± 0.1VDc 11). Full rated output voltage: 5 ± 0.2VDc 12). Short-term maximum output current: ≥1000mA 13). Maximum output current for a long time: ≥600mA 14). Voltage Regulation: ± 0.2% 15). Load regulation: ± 0.5% 16). Output ripple and noise (mVp-p): ≤50 17). Switch overshoot amplitude: ( rated input voltage, output load plus 10%) ≤5% VO 18). Output over-current protection: output maximum load of 150-200% A HLK-PM03 : AC-DC 220V to 3.3Visolating switch power supply module/ step-down module 1. Product features: 1. Meet UL, CE requirements, 2. Ultra-thin, ultra-small 3. All voltage input (AC: 90 ~ 264V) 4. Low ripple and low noise 5. Output overload and short circuit protection 6. High efficiency, high power density 7. The product is designed to meet the requirements of EMC and Safety Test 8. Low power consumption, environmental protection, no-load loss <0.1W 9.100% load aging and testing 10.1 year warranty perio 2. Environment Condition Item Name Technical Criteria Unit Operation Temperature -20— 60 Centigrade Store Temperature -40— 80 Centigrade Relative humidity 5—95 % Cooling way Cooling by radiation Atmospheric pressure 80—106 Kpa Sea level elevation ≤2000 m Vibration Vibration coefficient 10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes 3.Electrical Characteristic 1. Input characteristics (test at room temperature 20 C). Item Name Technical Criteria Unit Rated input voltage 100-240 VAc Input voltage range 90-264 VAc Maximum input current ≤0.2 A Input current surge ≤10 A maximum input voltage ≤270 VAc Enter slow start ≤50 mS Input Low Voltage Efficiency Vin=110VAc,Output full-load≥69 % Input High Voltage Efficiency Vin=220VAc,output full-load≥70 % Long-term reliability MTBF≥100,000 h Load rated output voltage 3.3±0.1 VDc Full rated output voltage 3.3±0.2 VDc Short-term maximum output current ≥1200 mA The maximum output current for a long time ≥1000 mA Voltage Regulation ±0.2 % Load Regulation ±0.5 % Output ripple and noise (mVp-p) ≤70 Rated input voltage, full load. Using 20MHz of bandwidth, The load side 10uF and 0.1uF capacitor to be tested. mV Switch overshoot amplitude (Rated input voltage and output load plus 10%)≤5 %VO Output over-current protection 150-200% of the output maximum load A Output short circuit protection Direct short circuit at the normal output, automatically resume normal operation after a short circuit removal 4.Safety Characteristics: 4.1 Products designed to meet UL, CE safety certification requirements. 4.2 Safety and electromagnetic compatibility Designed with the input of 0.5A UL certified insurance; PCB board using double-sided copper clad plate production, material for the 94-V0 fire rating level; Safety standards: Compliance with UL1012, EN60950, UL60950 Insulation voltage: I / P-O / P: 2500VAC Insulation resistance :I / PO / P> 100M Ohms / 500VDC 25 C 70% RH Conduction and radiation :comply with EN55011, EN55022 (CISPR22) Electrostatic discharge :IEC / EN 61000-4-2 level 4 8kV / 15kV RF radiation Immunity: IEC / EN 61000-4-3 See Application Note 4.3 Temperature safety design At room temperature,the capacitors of this power , the inner surface of the main converter maximum temperature does not exceed 90 C; Shell maximum surface temperature does not exceed 60 C HLK-PM12 Product Feature: Product features: 1. Meet UL, CE requirements, 2. Ultra-thin, ultra-small 2. All voltage input (AC: 90 ~ 264V) 3. Low ripple and low noise 4. Output overload and short circuit protection 5. High efficiency, high power density 6. The product is designed to meet the requirements of EMC and Safety Test 7. Low power consumption, environmental protection, no-load loss <0.1W 8.100% load aging and testing 9.1 year warranty perio Environment Condition Item Name Technical Criteria Unit Operation Temperature -20— 60 Centigrade Store Temperature -40— 80 Centigrade Relative humidity 5—95 % Cooling way Cooling by radiation Atmospheric pressure 80—106 Kpa Sea level elevation ≤2000 m Vibration Vibration coefficient 10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes Electrical Characteristic 1.Input characteristics (test at room temperature 20 Item Name Technical Criteria Unit Rated input voltage 100-240 VAc Input voltage range 90-264 VAc Maximum input current ≤0.2 A Input current surge ≤10 A maximum input voltage ≤270 VAc Enter slow start ≤50 mS Input Low Voltage Efficiency Vin=110VAc Output full-load≥69 % Input High Voltage Efficiency Vin=220VAc output full-load≥70 % Long-term reliability MTBF≥100,000 h Load rated output voltage 5±0.1 VDc Full rated output voltage 5±0.2 VDc Short-term maximum output current ≥1000 mA The maximum output current for a long time ≥600 mA Voltage Regulation ±0.2 % Load Regulation ±0.5 % Output ripple and noise (mVp-p) ≤50 Rated input voltage, full load. Using 20MHz of bandwidth, The load side 10uF and 0.1uF capacitor to be tested. mV Switch overshoot amplitude (Rated input voltage and output load plus 10%)≤5 %VO Output over-current protection 150-200% of the output maximum load A Output short circuit protection Direct short circuit at the normal output, automatically resume normal operation after a short circuit removal Safety Characteristics: 4.1Products designed to meet UL, CE safety certification requirements. 4.2Safety and electromagnetic compatibility Designed with the input of 0.5A UL certified insurance; PCB board using double-sided copper clad plate production, material for the 94-V0 fire rating level; Safety standards: Compliance with UL1012, EN60950, UL60950 Insulation voltage: I / P-O / P: 2500VAC Insulation resistance :I / PO / P> 100M Ohms / 500VDC 25C 70% RH Conduction and radiation :comply with EN55011, EN55022 (CISPR22) Electrostatic discharge :IEC / EN 61000-4-2 level 4 8kV / 15kV RF radiation Immunity: IEC / EN 61000-4-3 See Application Note 4.3 Temperature safety design At room temperature,the capacitors of this power , the inner surface of the main converter maximum temperature does not exceed 90 C; Shell maximum surface temperature does not exceed 60C
Step Down Module